Panasonic Split AC Error Codes / Kode Error AC Panasonic

How to check panasonic aircond error code?
How to reset panasonic air  conditioner?

Panasonic Air Conditioner Troubleshooting


Error code ac panasonic split

  • H00 No Abnormality Detected
  • H11 Indoor/Outdoor Abnormal Communication
  • H12 Indoor/Outdoor Capacity Rank j
  • H14 Indoor Intake Air Temperature Sensor Abnormality
  • H15 Outdoor Compressor Temperature Sensor > Abnormality
  • H16 Outdoor Current Transformer (CT) Open Circuit
  • H19 Indoor Fan Motor -DC Motor Mechanism> Locked
  • H21 Float Switch Continuous Open Circuit Abnormality
  • H23 Indoor Pipe Temperature Sensor 1 (bottom) Abnormality
  • H24 Indoor Pipe Temperature Sensor 2 (upper > Abnormalitu
  • H25 Nanoe- Abnormality
  • H27 Outdoor Air Temperature Sensor Abnormality
  • H28 Outdoor Condenser Pipe Temperature Sensor 1 (upper) Abnormality
  • H30 Outdoor Compressor Discharge Temperature Sensor Abnormality
  • H32 Outdoor Condenser Pipe Temperature Sensor 2 (lower de-frost) Abnormality
  • H33 Unspeci-fied Voltage between Indoor and Outdoor
  • H34 Outdoor PCB's IPM Heat Sink Temperature> Sensor Abnormality
  • H35 Drainage or Drain Pump Abnormality
  • H36 Outdoor Gas Pipe Temperature Sensor Abnormality
  • H37 Outdoor Liquid Pipe Temperature Sensor X Abnormality
  • H38 Model Code Mismatch
  • H39 Abnormal Standby Indoor Unit in Multi System
  • H41 Abnormal Indoor Unit in Multi System
  • H58 Patrol Gas Sensor Abnormality
  • H59 Human Activity Sensor Abnormality
  • H64 High Pressure Switch Abnormality
  • H70 Light Sensor Abnormality
  • H97 Outdoor Fan Motor (Type 1) DC Motor > Mechanism Locked
  • H97 Outdoor Fan Motor (Type 2 & Type 3) DC> Motor Mechanism Locked
  • H98 Indoor High Pressure Protection
  • H9C Indoor unit Freeze Prevention Protection
  • F11 4-way Valve Switching Failure
  • F17 Indoor Standby Unit Freezing (Multi System)
  • F90 Power Factor Correction Protection (PFC)
  • F91 Refrigeration Cycle Abnormality
  • F94 Outdoor Compressor Discharge Pressure Overshoot Protection
  • F95 Cooling High Pressure Abnormality
  • F96 IPM (Power Transistor) Overheating
  • F97 Compressor Overheating
  • F98 Input Over Current Detection (Current Transformer)
  • F99 DC Peak Current Detection

Error Code AC Panasonic F16-01

Cassette, Split Duct, Central, VRV

Error code AC panasonic F16-01

Air Swing Motor Abnormality

Kode error ac panasonik f16-01

Malfunction Decision Conditions

1. When the louver switch is not input.
Read : Panasonic split error codes

Malfunction Caused

1. Air swing motor
2. Indoor main PCB
3. Connector half-inserted.

Troubleshooting

Caution
For safety reason and to prevent component breakdown, always switch off the power before remove and connect the component.

Diagram kode error Ac panasonik f16-01

Error code AC Panasonic F15-01

Cassette, Split Duct, Central, VRV

Drain water level floating switch abnormality

error code panasonic f15-01
Read to: Panasonic split ac error codes

Malfunction Decision Conditions

1. When water level is not on the rise.
2. When floating switch is turned OFF.

Malfunction Caused
1. Faulty indoor unit PCB
2. Faulty drain motor.
3. Floating switch
4. CN-TH2 pin 1 or 2 disconnected
5. Drain hose clogged

Baca juga: Cara membuka remote AC yang terkunci

Troubleshooting

Caution
For safety reason and to prevent component breakdown, always switch off the power before remove and connect the component
error code panasonic f15-01